AU SX

AU SX

Information
Technical data
Compliance
Download
Type 2 control unit for Ilion and Ulisse photocells

Control unit for safety photocells Ilion and Ulisse, which can be combined to form a Type 2 safety system.

  • Up to 4 photocells may be connected
  • Guided-contact safety relays
  • Start/Restart interlock
  • EDM Feedback input for external contactors monitoring
  • Self test every 5 seconds
Number of photocells1 ... 4
Safety relay outputs2 N.O. - 2 A 250 VAC
Status outputPNP - 100 mA at 24 VDC
Response time (ms)<= 30
Start/restart commandManual or automatic. Start/Restart selectable on terminal block
External Device MonitoringYes - EDM Feedback input for external contactors monitoring
SignallingLED indication of input/output status and diagnosis
Power supply (VDC)24 ± 20%
Electrical connectionsOn terminal block
Operating temperature (°C)0 ... 55
Protection ratingIP 20 for housing - IP 2X for terminal block
FasteningOn DIN rail fastening according to EN 50022-35 standard
Dimensions h x w x d (mm)99 x 22,5 x 114
  • 2006/42/EC: Machine Directive
  • 2014/30/EU: Electromagnetic Compatibility Directive
  • 2014/35/EU: Low Voltage Directive
  • EN 61496-1:2013 Safety of machinery. Electro sensitive protective equipment. General requirements and tests
  • IEC 62061 (ed.1) (SILCL 1) Safety of machinery. Functional safety of safety-related electrical, electronic and programmable electronic control systems
  • EN ISO 13849-1:2008 (Cat. 2, PL c) Safety of machinery. Safety-related parts of control systems. Part 1: General principles for design
  • EN 50178:1997 Electronic equipment for use in power installations
  • EN 55022:2010 Information Technology Equipment. Radio Disturbance Characteristics. Limits and Methods of Measurement
  • UL (C+US) mark for USA and Canada
Certifications:

Lista modelli - AU SX

Available models

Model Description Code